Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201311685 - Two Employees Are Injured in Building Collapse

Accident Summary Nr: 201311685 -- Report ID: 0213400 -- Event Date: 05/15/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31014691505/15/20071542236220Buontempo

Abstract: Employees #1 and #2 were working in a building under construction when it collapsed. Employee #1 suffered an unspecified injury and did not require hospitalization. Employee #2 also suffered an unspecified injury but did require hospitalization.

Keywords: COLLAPSE, CAUGHT BY, CONSTRUCTION, CONTUSION
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $1,000,000 to $5,000,000 3 35

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310146915 Hospitalized injury Bruise/Contus/Abras Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior masonry
Fatality Cause: Collapse of structure
2 310146915 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior masonry
Fatality Cause: Collapse of structure

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close