Accident Report Detail
Accident Summary Nr: 201282779 - Employee Decapitated When Tank Explodes
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 311034268 | 08/21/2007 | 3559 | 333298 | Advance Industrial Maintenance & Machine, Inc. |
Abstract: Employee #1 was welding a stainless steel connection on a 540- gallon mixing tank for the installation of a flow meter. The tank previously contained sodium methylate and had been purged over night using compressed air. The welding began at approximately 10:30 a.m. Employee #1 went to lunch at approximately 11:50 a.m. and the tank was purged again from noon until approximately 12:45 p.m. Employee #1 resumed welding once the air line was disconnected. At approximately 1:30 p.m. an explosion occurred. The top of the tank blew off and became lodged in the ceiling of the metal building. Employee #1 was thrown from the tank and had been decapitated. A small fire occurred during the explosion and was quickly extinguished by the fire department. Employee #1 was killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 311034268 | Fatality | Amputation | Welders and cutters |
Translate