Accident Summary Nr: 201271004 - Employee killed when struck by load of rebar

Accident Summary Nr: 201271004 -- Report ID: 0418300 -- Event Date: 06/20/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30342366906/20/200017910New Life Steel

Abstract: Employee #1 was preparing a load for a crane to unload from a commercial vehicle. He rigged two 20 ft long bundles of rebar end to end, creating a 40 ft long, two-section bundle. He then stood on the truck next to the rebar and signaled the crane operator to begin lifting the bundles. When they were at a height of approximately 4 ft above the bed of the truck, they began to rotate and then scissored, striking Employee #1 in the head. He was killed.

Keywords: HEAD, HOISTING MECHANISM, UNSECURED, WORK RULES, LOAD SHIFT, SUSPENDED LOAD, CONSTRUCTION, OFF LOADING, STRUCK BY, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition $1,000,000 to $5,000,000 4 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 303423669 Fatality Concussion Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause: Lifting operations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.