Accident Summary Nr: 201262813 - Employee's hand is amputated by power press

Accident Summary Nr: 201262813 -- Report ID: 0524200 -- Event Date: 06/05/2010
Inspection NrDate OpenedSICNAICSEstablishment Name
31468639507/26/20103469332116Tempel Steel Company

Abstract: At approximately 1:30 pm on June 5, 2010, Employee #1, of Tempel Steel Company, was working on a mechanical power press that was set on a continuous mode so the employee did not have to put a hand in the die near the point of operation. The press had interlock gates on the front of the machine. Employee #1 opened the interlock gate to reach into the die opening and his left hand was amputated.

Keywords: DIE, AMPUTATED, POWER PRESS, INTERLOCK, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 314686395 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.