Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201204096 - Worker Crushed Inside of Trash Compacting Truck

Accident Summary Nr: 201204096 -- Report ID: 1054114 -- Event Date: 03/09/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31270399403/09/20094212562111Sanipac Inc

Abstract: On March 9, 2009, Employee #1, a sanitation worker, was collecting garbage and recyclable materials. He entered the compactor section of the garbage truck to clean up fallen material. As he was working inside the truck the compactor cycled and crushed him to death.

Keywords: GARBAGE TRUCK, CRUSHED, TRASH COMPACTOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 312703994 Fatality Asphyxia Truck drivers, heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close