Accident Summary Nr: 201203213 -- Report ID: 1054114 -- Event Date: 05/22/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30942245905/22/20061794238910Highland Excavation & Trucking Llc

Abstract: On May 22, 2006, Employees #1 and a coworker were installing a 10 in. diameter sewer line in an approximately 36 in. wide by 7 ft 3 in. deep trench. They finished putting in the first section of pipe and tamped it in with a mechanical tamper. The employees then had the excavator dig out for the next length, put bedding rock down, and install the second section of pipe in the trench. They were using a laser to make sure it was on grade when a coworker standing near the trench saw the north wall start to move and shouted out a warning. The wall caved in on them, completely covering the coworker and burying Employeee #1 up to his waist. Both workers were successfully extricated. Employee #1 suffered a cracked rib and bruised shoulder where he was struck by a large clod of the clay dirt. The coworker also suffered a cracked rib, as well as a small puncture to his lung, which quickly closed. Both employees returned to work within seven work days. The trench had been dug in clay soil, but a natural gas line had been installed 16 to 18 in. to the north and about 48 to 52 in. deep. This left an approximately 12 in. wide clay wall of original material between the two excavations, which is what had toppled into Employee #1's trench. In addition, the trench in which the pipe was being installed was not shored or otherwise protected against cave-ins. There had been heavy rains in the area during the night before the accident.

Keywords: EXCAVATION, FRACTURE, LUNG, CONSTRUCTION, TRENCH, VIBRATIONS, RIB, SHORING, UNSTABLE SOIL, CAVE-IN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $1,000,000 to $5,000,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 309422459 Hospitalized injury Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Wall (earthen) collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.