Accident Summary Nr: 201203031 - Employee's Fingers Are Amputated in Chipper

Accident Summary Nr: 201203031 -- Report ID: 1054114 -- Event Date: 12/09/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30941916612/13/20052436321212Freres Lumber Co Inc

Abstract: At approximately 11:20 p.m. on December 9, 2005, Employee #1 was attempting to remove wood debris from the in-feeder of a chipper, at Freres Lumber. He had raised the guard over the in-feeder to allow access to the debris that was causing a blockage. He was injured when the glove on his right hand got caught and his hand was pulled into the in-feed. He was hospitalized for the amputation of his little finger and a portion of the ring finger on his right hand.

Keywords: WOOD CHIPS, AMPUTATED, FINGER, GUARD, WORK RULES, CHIPPER, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309419166 Hospitalized injury Amputation Milling and planing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.