Accident Summary Nr: 201201381 - Two employees injured when elevator collapsed

Accident Summary Nr: 201201381 -- Report ID: 1054114 -- Event Date: 05/25/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
30406953705/25/200124360Mckenzie Forest Products Llc

Abstract: At 1:35 p.m. on May 25, 2001, two workers were unloading plywood 4-foot by 8-foot sheets from the hot press. They were near finishing the unloading at the top of the elevator used to unload the press outfeed. The two-point chain hoist shaft shifted horizontally, kicking the motor drive chain from the shaft hoist ball sprocket. When the shaft shifted, it blocked the safety brake, which prevented it from setting and preventing the lift from falling. The shifted brake surface on the shaft blocked the brake shoes from setting on the brake surface. The 15 foot free fall of the platform resulted in both Employee #1 and Employee #2 being hospitalized with both of their heel bones of their feet fractured and smashed.

Keywords: FRACTURE, COLLAPSE, FALL, ELEVATOR, FOOT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 304069537 Hospitalized injury Fracture Machine operators, not specified
2 304069537 Hospitalized injury Fracture Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close