Abstract: Employee #1 was assigned to feed a multiple-rip lathe machine. He was shown how to unjam the machine by shutting it off using the control button and opening the access doors to the saws. The saw had jammed four times prior to the accident and Employee #1 had cleared the jams by shutting the saw off with the control button located adjacent the machine, opening the access doors and clearing the obstruction. At the time of the accident, Employee #1 thought he could clear the saws by leaving them running and using a stick to remove the obstruction. During this process, Employee #1's fingers contacted the saws amputating the tip of his right forefinger and fracturing his right middle finger. Employee #1 was hospitalized.

Keywords: AMPUTATED, JAMMED, SAW, FRACTURE, LATHE, FINGER, LOCKOUT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 302295076 Hospitalized injury Amputation Excavating and loading machine operators
2 302295068 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.