Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201185543 - Employee's Finger Is Injured When Ring Is Caught on Bolt

Accident Summary Nr: 201185543 -- Report ID: 0950611 -- Event Date: 01/16/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31269066203/11/20114911221122Pg&E

Abstract: On January 16, 2011, Employee #1, an apprentice telecommunication technician with the General Construction section of PG&E, was wiring a telecom cabinet on the second floor of a building. A grid of racks called "ladder racks", installed approximately 7.5 ft above the floor, was used to run cables to telecom equipment. Employee #1 was standing on the first rung of a self-locking portable ladder, labeling the cables. The ladder rack had a few small bolts with exposed threads protruding horizontally. While descending the ladder and holding the rack for balance, his wedding ring became caught on a protruding bolt. Employee #1 was hospitalized at St. Francis Hospital for removal of the ring and treatment of the laceration. He subsequently had surgery at CPMC-Davies Campus. The employer's safety rules prohibit wearing jewelry where there is a danger of electrical contact, crushing or snagging on machinery, materials, or other objects. Employee #1 had been informed of that policy a couple of weeks before the incident.

Keywords: TELECOM WORK, FINGER, LADDER, RING, CAUGHT BY, DESCENDING, LACERATION, BOLT, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 312690662 Hospitalized injury Cut/Laceration Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close