Accident Summary Nr: 201182656 - Employee's face is injured by flying object

Accident Summary Nr: 201182656 -- Report ID: 0950611 -- Event Date: 07/29/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30739325608/04/20051522236116Angotti & Reilly, Inc.

Abstract: At approximately 10:30 a.m. on July 29, 2005, Employee #1 was shaping a 0.25-in. thick steel bucket with a Bosch 1347A portable right-angle grinder (Serial Number R1880022170). It had no safety guard and its screw-in handle was missing. After trying several new SAIT 22021 type-27 4.5-in. wheels that day, he selected a wheel comparable to the rated rpm rate of the grinder. He first cut was an approximately 8-in length off the bucket and experienced some wheel binding and jerking problems. His supervisor then explained to him that he needed to cut off more steel on the same bucket, and that he needed to cut at an angle to avoid disturbing other components of the grinder. After the supervisor left, Employee #1 began cutting at an approximately 45-degree angle. The wheel snagged the body of the grinder, causing the abrasive wheel to break apart and dislocated from the spindle. Flying debris ejected from the grinder and struck Employee #1 in his face. Employee #1 was not wearing a face shield, but was wearing ANSI labeled safety glasses. The impact of the flying debris upon his face caused two facial lacerations and a broken nose. He was transported to a medical center, where he was hospitalized for surgical procedures and postoperative care and then released four days later. Citations issued were a failure to use a grinder guard, sound and check the RPM before the wheel was used, to receive training for grinder safety, and use eye and face protection.

Keywords: GRINDER, STRUCK AGAINST, STRUCK BY, FLYING OBJECT, ABRASIVE WHEEL, FACE, GRINDING MACHINE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $1,000,000 to $5,000,000 2

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 307393256 Hospitalized injury Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior cladding
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.