Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201174992 - Employee is injured while unloading structural steel

Accident Summary Nr: 201174992 -- Report ID: 0950621 -- Event Date: 10/23/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
12034397511/18/20031791238120Herrick Co.

Abstract: At approximately 8:30 a.m. on October 23, 2003, Employee #1, an ironworker, was unloading a truckload of structural steel using multi-piece "pick and rigging." While attaching the slings to a column, it fell over and pinned the employee's leg against another column located behind him. He was transported to the U.C. Davis Medical Center in Sacramento, CA, where he was hospitalized and treated for a broken left leg and crushing-type tissue damage.

Keywords: FRACTURE, STEEL, PINNED, COLUMN, CONSTRUCTION, CRUSHED, STEEL ERECTION, STRUCK BY, SLING, LEG
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition $5,000,000 to $20,000,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 120343975 Hospitalized injury Fracture Structural metal workers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Steel Erection Of Solid Web-Landing Materials (Hoi
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close