Accident Summary Nr: 201170438 - FALL FROM LADDER

Accident Summary Nr: 201170438 -- Report ID: 0950621 -- Event Date: 05/13/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12579437008/21/199748130Roseville Telephone Company

Abstract: A communications worker was working alone in a telephone vault. He had placed a 3.7-meter-long ladder in the vault to enter and exit. The ladder had hooks at the top for placement over the top step of vault entrance, but the employee had not secured the ladder to the step. The top step of the vault was improperly placed, requiring those descending to climb toward the wall instead of the open area of the vault. Additionally, the bottom of the ladder was apparently resting on the floor of the vault, which was covered by about 150 millimeters of water. As he was climbing up the ladder to return to his truck to confirm that the proper circuit was being replaced, the ladder slipped out, moving across the concrete floor and causing the employee to fall to the floor of the vault. The employee broke his leg in the fall and was unable to exit the vault. A resident heard his calls 2 hours after the accident and summoned emergency rescue services. The employee was hospitalized for his injuries.

Keywords: FRACTURE, TELECOM WORK, UNSECURED, LADDER, UNDRGRD INSTALLATION, FALL, SLIPPERY SURFACE, MANHOLE, COMMUNICATION WORKER, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125794370 Hospitalized injury Fracture Telephone line installers and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close