Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201167384 - Employee Injures Spine in Fall from Scaffold

Accident Summary Nr: 201167384 -- Report ID: 0950641 -- Event Date: 09/21/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
12615672810/06/20051799238990Orange County Scaffold

Abstract: At approximately 2:30 p.m. on September 21, 2005, Employee #1, a carpenter, was working with two coworkers, installing the scaffolding on the south side from where the man lift was removed. Employee #1 was erecting the scaffold while the two coworkers were delivering different components of the scaffold. Employee #1 was securing the guardrails by tying the wire. When he tried to stepped out of one scaffold and over to another, instead of using a ladder, he slipped and fell to the ground, sustaining injuries to his spine and right leg. He was transported to UCLA Medical Center, where he was hospitalized for treatment.

Keywords: FRACTURE, GUARDRAIL, SPINE, CARPENTER, LADDER, SLIP, CONSTRUCTION, FALL, LEG, SCAFFOLD
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $5,000,000 to $20,000,000 10 75

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 126156728 Hospitalized injury Fracture Carpenters Distance of Fall: feet
Worker Height Above Ground/Floor: 27 feet
Cause: Exterior painting
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.