Accident Summary Nr: 201166535 - Employee Injures Hand Using Table Saw

Accident Summary Nr: 201166535 -- Report ID: 0950641 -- Event Date: 03/16/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
12615129903/29/20057359532299Rick Doten Production Inc

Abstract: On March 16, 2005, Employee # 1 and a coworker were working in a one-story warehouse performing woodworking and minor set construction. Employee #1 was constructing a cabinet creating a horizontal non-through cut on a 4-ft by 4-ft board that would serve as the slide guides for the cabinet doors. Employee #1 removed the blade guard and spreader, while holding each end of the boards, Employee #1 placed it atop the rotating dado blade, dropping it atop the rotating blade. Employee #1 started the cut, the wood kicked back, it caused him to lose his balance and put his left hand atop the 10-inch rigid rotating blade, table saw Model TS2412-0. Employee #1 sustained a laceration to his left third and fourth finger, and a fracture of his fourth finger. Employee #1 was hospitalized and received surgery on his injured hand.

Keywords: BOARD, FRACTURE, FINGER, GUARD, LACERATION, DOOR, HAND, TABLE SAW

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 126151299 Non Hospitalized injury Cut/Laceration Painters, sculptors, craft-artists & printmakers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close