Accident Summary Nr: 201163466 - Employee sustains emotional trauma in excavation cave-in

Accident Summary Nr: 201163466 -- Report ID: 0950641 -- Event Date: 02/04/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
12610224302/04/200217940Beryl Lockhart Enterprises Inc.

Abstract: At approximately 8:10 a.m., on February 4, 2002, Employee #1 and a coworker were drilling a 75-ft-deep hole at a construction site located in St. Pacific Palisades, California. Employee #1 was a "swapper" while the coworker was a drill rig operator. The hole was dug to approximately 13 ft in depth and was slightly larger than 45 in. in diameter. While the auger was still 8 ft inside the hole and as it was being raised by the coworker using the drill rig, the surrounding soil, which was 3 to 4 ft around the perimeter of the excavation hole became unstable and caved in. At the time of accident, Employee #1 was working approximately 4 ft away from the perimeter of the hole, thus he fell inside the hole as it caved in. Employee #1 was buried by soil over his head and became unconscious for an undetermined length of time. Employee #1 was extricated by the Los Angeles Fire Department, and transported to University of California, Los Angeles (UCLA) Medical Center where he stayed for treatment of emotional trauma, a scrape on his left cheek, and dirt in his eyes for 2 hours. He was then released.

Keywords: EYE, RIGGING, CONSTRUCTION, SHAFT, AUGER, FALL, BURIED, CAVE-IN, FACE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Contractor's yard/facility New project or new addition Under $50,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 126102243 Hospitalized injury Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 13 feet
Cause: Erection of coffer dams, caissons
Fatality Cause: Fall, other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.