Accident Summary Nr: 201163367 - Employee killed in fall from scaffold after electric shock

Accident Summary Nr: 201163367 -- Report ID: 0950641 -- Event Date: 12/03/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
12611490912/03/200117420Covello Plastering Corporation

Abstract: On December 3, 2001, Employee #1 and a coworker arrived at a worksite and were instructed to continue the lathing job started months ago at the same location. It was Employee #1's first day at the site. They were using an approximately 36 ft tall stationary metal scaffold to access the top section of the building; the scaffold was situated near an energized, 16,000-volt overhead power line. At the time of the accident, the coworker was on the roof putting screws in the air conditioning frame and talking with Employee #1, who was between 3 ft and 6 ft away. Employee #1 was standing on the northeast corner of the scaffold, holding a 10 ft long metal milker. He was handling the metal strip when it contacted the overhead power line, creating a spark. The coworker heard an explosion and saw the spark. He stood up just as Employee #1 fell off the scaffold to the ground. The coworker ran down and screamed for help. Another coworker, who was having lunch in the front of the building and saw the spark, went to investigate. He found Employee #1 lying on the ground, face up, and the coworker trying to help him. This second coworker called emergency services and Employee #1 was transported to UCLA Medical Center, where he died the following morning. The employee's supervisor was not onsite at the time of the accident. The employer did not ensure that operations, erections, handling, or transportation of tools, machinery, materials, structures or scaffolds, the moving of any house or other building, or any body parts maintained safe clearances from energized overhead lines. The employer was cited for a violation T8CCR 2946 (b)(2), provisions for preventing accidents due to proximity to overhead lines.

Keywords: CLEARANCE, OVERHEAD POWER LINE, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, ELEC CIRC PART--MISC, FALL, METAL STRIP, SCAFFOLD
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling Alteration or rehabilitation Under $50,000 3 36 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 126114909 Fatality Electric Shock Plasterers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Plastering
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close