Accident Summary Nr: 201161692 - Employee injured in trench cave-in

Accident Summary Nr: 201161692 -- Report ID: 0950641 -- Event Date: 07/29/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
12622065607/29/200017990Deck King Water Proofing Inc

Abstract: At approximately 10:15 a.m. on July 29, 2000, Employee #1, of Deck King Waterproofing, Inc., was in the east end of a 3 ft wide by 8 ft deep by 27 ft long trench. He was digging with a pick and shovel while a coworker did the same on the west end of the trench. Two other coworkers were at the top of the trench removing dirt with shovels. Approximately 10 minutes after the coworker exited the trench, the east end of the excavation collapsed on Employee #1, burying him to his neck. The coworker and a colleague quickly entered the trench and began to dig him out. A third coworker called 911. The fire department arrived at approximately 11:00 a.m. and were able to extricate Employee #1 after about after 2 1/2 hours. He was transported to Martin Luther King Hospital, where he was treated for minor injuries to his right leg and the released. Subsequent investigation revealed that the trench had no cave-in protection, such as shoring, sloping, or benching. In addition, there was nothing to prevent the soil piles on the surface from rolling back into the trench.

Keywords: EXCAVATION, TRENCH BOX, WORK RULES, CONSTRUCTION, TRENCH, SHORING, SLOPING, BURIED, CAVE-IN, LEG
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling Maintenance or repair $500,000 to $1,000,000 2 30

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 126220656 Non Hospitalized injury Bruise/Contus/Abras Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.