Accident Summary Nr: 201161460 - Employee is killed when sling breaks and load falls on him

Accident Summary Nr: 201161460 -- Report ID: 0950641 -- Event Date: 01/11/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
12609749201/11/200017990Malcolm Drilling Co.

Abstract: At approximately 8:00 a.m. on January 11, 2000, a fork lift truck operated by the general contractor on site was used to unload a truck. This truck contained steel shapes of I-Beams, angles, flat bars, and channels. The employer had its senior supervisor, two riggers and a record keeper assigned to receive and unload this delivery. The employer reported the unloading was discussed by the supervisor with his men and the slings were inspected. The forklift unloaded six pieces of angles weighing 2,322 pounds, and four pieces of flat bars weighing 1,225 lbs. This was reported to be ineffective and the employer arranged for a 250-ton crane owned and operated by Bragg Crane to do the job. The crane was equipped with 10 ft wire rope slings. The employer added nylon slings to the wire rope slings to spread the load. They first picked four pieces of I-Beams weighing 8,800 lbs. This was lifted from the truck over the boom of a 28-ton crane parked alongside the truck into the stacking area. The second pick consisted of two pieces of I-Beams weighing 5,200 lbs. The supervisor left and assigned the record keeper to coordinate the work. The flagman instructed the employees to lift everything in one load. The third load consisted of 12 pieces of steel channels weighing 24,480 pounds. This load was over the rated capacity of the nylon slings which was only 6,900 pounds in a choker hitch. A sling broke and the load crushed Employee #1, killing him.

Keywords: CRANE BOOM, SUSPENDED LOAD, BROKEN CABLE, CRUSHED, INDUSTRIAL TRUCK, SLING, BROKEN CHAIN, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition $20,000,000 and over 7 80 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 126097492 Fatality Other Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause: Crushed/run-over of non-operator by operating cons

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.