Accident Summary Nr: 201152568 - Employee Suffers Head And Back Injuries In Fall

Accident Summary Nr: 201152568 -- Report ID: 0950633 -- Event Date: 06/04/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
12589955910/06/199917990Janus Corporation

Abstract: On July 4, 1999, Employee #1 was part of an asbestos-removal crew working to remove asbestos from the interior of a church. Employee #1 and a coworker disassembled the top (third) section of a mobile scaffold and placed the removed section on top of the scaffold planks on the second level. They moved the scaffold to another location. When Employee #1 climbed back up the scaffold, he grabbed the third level brace that was sitting on top of the scaffold. The unsecured section of the scaffold slid toward Employee #1 and he lost his balance and fell from the side of the tower. Employee #1 was not trained on the erection and dismantling of the scaffold, and the erection and dismantling of the scaffold was not performed under the supervision and direction of a qualified person. Employee #1 sustained a head injury and was transported to the hospital and admitted into the intensive care unit with a diagnosis of a "closed head injury".

Keywords: HEAD, DISMANTLING, UNSECURED, CONSTRUCTION, ASBESTOS REMOVAL, BRACE, FALL, LOST BALANCE, UNTRAINED, SCAFFOLD
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building Alteration or rehabilitation Under $50,000 20

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 125899559 Hospitalized injury Other Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: 11 feet
Cause: Interior masonry
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.