Accident Summary Nr: 201150729 - EMPLOYEE INJURED IN FALL FROM UTILITY POLE

Accident Summary Nr: 201150729 -- Report ID: 0950633 -- Event Date: 06/12/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
11995752008/01/199717310Secc Cable Communications

Abstract: A cable television line worker was working from a 15.2-meter-tall wood utility pole. He was about 6.1 meters above the ground when he fell from the pole. He was hospitalized with a fractured pelvis, left elbow, and left eyebrow.

Keywords: EYE, FRACTURE, TELECOM WORK, CABLE TV WORK, PELVIS, FALL, ELBOW, UTILITY POLE, COMMUNICATION WORKER
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Powerline, transmission line Maintenance or repair Under $50,000 50

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 119957520 Hospitalized injury Fracture Telephone line installers and repairers Distance of Fall: feet
Worker Height Above Ground/Floor: 20 feet
Cause: Fencing, installing lights, signs, etc.
Fatality Cause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.