Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201147410 - Employee Is Burned While Repairing Autoclave

Accident Summary Nr: 201147410 -- Report ID: 0950631 -- Event Date: 10/14/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
12595159012/12/20052834325412Teva Sicor

Abstract: On October 14, 2005, Employee #1, a maintenance technician with a pharmaceutical manufacturer, was removing a leaking valve from a Fedegari Autoclave II prior to draining the system completely. As he opened the valve, he was splashed with steam and hot water. Employee #1 was hospitalized with second-degree degree burns from his mid-chest to his mid-thigh, and on his left arm.

Keywords: BURN, CHEST, LEAK, STEAM LINE, ABDOMEN, REPAIR, STEAM, VALVE, HOT WATER, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125951590 Hospitalized injury Burn/Scald(Heat) Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close