Accident Summary Nr: 201140985 - Employee Injured When Equipment Fell on Leg
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 120245568 | 04/27/1999 | 5082 | 0 | Recat |
Abstract: Employee #1 was removing parts from a road grader that was up on blocks. Although the hydraulic pumps had been removed, the mechanical action of the grader's weight resting on a cylinder had caused hydraulic pressure in one of the 24 hydraulic lines. When that line was loosened, it released the pressure on the "wheel lean" mechanism, causing the grader to shift position. The blocks were knocked out, and the grader dropped, catching Employee #1 and resulting in multiple fractures to both his legs. Employee #1 was hospitalized.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120245568 | Hospitalized injury | Fracture | Heavy equipment mechanics |