Accident Report Detail
Accident: 201140480 - Employee Injured In Fall From Crane
Inspection | Open Date | SIC | Establishment Name |
---|---|---|---|
125910489 | 11/07/1997 | 7996 | Disneyland |
Employees were attempting to set a hopper filled with dirt up onto a ledge on the Matterhorn ride. The employees were using a Link Belt All Terrain Crane, Model HSP 8050, Serial Number 53I2- 0649. As the crane operator was lifting the load, the crane began to tip. As the crane tipped, Employee #1, an ironworker and a coworker, a welder, stepped onto the outrigger to add counterweight to the crane. The coworker jumped off the outrigger, but Employee #1 remained on the outrigger. As the crane tipped, Employee #1 was propelled up and through a mushroom in the Alice in Wonderland attraction before he jumped off the outrigger. Employee #1 sustained a broken right ankle along with some abrasions and contusions as a result of this accident and was hospitalized. The causal factor to the accident would be that the crane was loaded beyond its rated capacity.
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 125910489 | Hospitalized injury | Fracture | Structural metal workers |