Accident Summary Nr: 201140456 - electric shock - direct contact with energized parts

Accident Summary Nr: 201140456 -- Report ID: 0950631 -- Event Date: 10/22/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12590910111/10/199738510Reynard Corporation

Abstract: An employee was working on a lens-coating machine. He was standing on a small stepladder to reach a view port in the vacuum chamber of the machine. He slipped from the ladder and fell into energized electric parts in the lower section of the machine. He received a severe electric shock for which he was hospitalized.

Keywords: E GI II, ELEC PROTECT EQUIP, MAINTENANCE, ELECTRICAL, LADDER, UNGUARDED LIVE PARTS, ELECTRIC SHOCK, FALL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125909101 Hospitalized injury Electric Shock Optical goods workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.