Accident Summary Nr: 201129491 - Employee Is Injured in Fall Through Floor Opening

Accident Summary Nr: 201129491 -- Report ID: 0950613 -- Event Date: 10/17/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31577507210/17/20121541236220Swinerton Builders

Abstract: At approximately 6:30 a.m. on October 17, 2012, Employee #1 was instructed by his supervisor during an early morning meeting to remove the barricade railing on the second floor and extend the railing outwards towards the center of the building. This job site was at the north end of building Hilltop E. The railings were being moved in order for the stonecutter to cut a hole on the concrete floor where the railing was located. The employee asked a coworker to go to the first floor below and put caution tape barricade on the area where the stonecutters will be cutting the floor so that no other employees would be exposed to the falling debris hazards. According to Employee #1, the supervisor did not inform him that there was a floor opening in that work place vicinity, nor did he inform him to wear fall protection. The barricades railing did not go all the way around. The employee stated that only two sides of the floor opening were barricaded instead of all four sides. The employer stated that the accident scene was not disturbed and preserved until CSHO arrived. There was no evidence that two other railings were installed to guard the two remaining openly exposed sides of the floor opening. Employee # 1 worked alone as he commenced to remove the railings. As he removed his first railing, he stepped into a piece of plywood that tilted on to a floor opening. A grey plastic sheet that concealed the floor opening covered the floor opening. Employee #1 slid on the plywood and fell through the floor opening breaking the grey plastic and falling to the first floor approximately 15 to 20-ft below. The employee was transported to an area hospital, where he was treated for multiple head and body fractures. Employee #1 remains hospitalized.

Keywords: FRACTURE, HEAD, COVER, RAIL, BARRIER GUARD, FALL, FALL PROTECTION, FLOOR OPENING
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building Alteration or rehabilitation $500,000 to $1,000,000 2

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 315775072 Hospitalized injury Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: 14 feet
Cause: Interior carpentry
Fatality Cause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.