Accident Summary Nr: 201129004 - Employee Falls from Roof; Suffers Several Fractures

Accident Summary Nr: 201129004 -- Report ID: 0950613 -- Event Date: 02/18/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31577409103/29/20127342561710Terminix International, Inc.

Abstract: At approximately 8:30 a.m. on February 18, 2012, a Terminix crew was assigned to aerate a home following fumigation; this included the removal of tarps from the roof of the single-story structure. The crew leader allowed Employee #1 to be on the roof without any form of fall protection. The tarps were covering an unmarked or unidentified opening in the roof which made it appear that the roof extended past the chimney. Employee #1 fell approximately 11 feet as he walked past the chimney on the tarps believing there was a solid roof below, suffering torn knee and fractures to his pelvis, vertebrae, and fingers. Employee #1 was taken to Stanford Hospital where he was treated for injuries including compression fractures of his spine and a broken hand; he was released from the hospital two days later.

Keywords: KNEE, TENDON, ROOF, SPINE, PELVIS, FALL, FALL PROTECTION, VERTEBRA, CHIMNEY, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 315774091 Hospitalized injury Fracture Pest control occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close