Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201117926 - Employee Suffers Fracture In Fall From Roof

Accident Summary Nr: 201117926 -- Report ID: 0950643 -- Event Date: 05/14/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
12031939706/09/20041761238160Mayer Roofing Inc

Abstract: On May 14, 2004, Employee #1 was on the roof of a house under construction. Employee #1 climbed up a ladder to the second level of the two-story house. This portion of the house had two roof levels, one at 13 ft 6 in. and the other at 19 ft 8 in. to the edge. Both roof levels were located on the entry side of the house. Employee #1 fell from the rear side of the house. Employee #1 was marking chalk lines on the roofing paper in preparation for laying the tiles when he slipped on a nail and fell 26 in. from the second-level roof onto the lower level roof. Employee #1 then slid 14 ft on the sloped roof and fell13 ft 6 in. to the ground. A coworker on the other side of the house saw Employee #1 on the second-level roof. The coworker said that he called Employee #1, who was his brother, to tell him it was time to leave. The coworker heard Employee #1 calling his name and it sounded like it was coming from down on the ground. When the coworker walked to that side of the house, he saw Employee #1 lying on the ground and he immediately climbed down the ladder and called medical assistance. Employee #1 suffered fractures to his right arm. Employee #1 was hospitalized for four days, had surgery on his right arm, and had a metal rod inserted from his shoulder to his elbow.

Keywords: FRACTURE, ROOF, SHOULDER, SLIP, CONSTRUCTION, ROOFER, FALL, FALL PROTECTION, ELBOW, UNGUARDED
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition Under $50,000 2 19

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 120319397 Hospitalized injury Fracture Roofers Distance of Fall: feet
Worker Height Above Ground/Floor: 19 feet
Cause: Roofing
Fatality Cause: Fall from roof

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.