Accident Report Detail

Accident Summary Nr: 201117819 - Employee amputates fingers while performing well repairs

Accident Summary Nr: 201117819 -- Report ID: 0950643 -- Event Date: 07/06/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30082777108/04/20041781237110Archie Floyd'S Roadrunner Pump Service

Abstract: At approximately 8:10 a.m. on July 6, 2004, Employee #1, a 22-year-old laborer, and a coworker were using a truck mounted hoist to pull piping and a pump from a well in order to replace a pump. A synthetic coated wire rope, intended to secure bicycles, was used as a sling. As they were extracting the pipe and pump, the pump shifted, and the makeshift sling broke. The tips of Employee #1's middle and ring fingers on his left hand were amputated. The employer was a pump and pipeline service contractor that installs and replaces water wells and related equipment. Employee #1 had been employed by this contractor for 3 months and performing the duties of a customer service representative, which included pump replacement. A detailed investigation was conducted, and Employee #1 and the coworker were interviewed. The investigation concluded that a violation of California Code of Regulation, Title 8 Section 5045(a) had occurred. As a result, the Division issued general citation for California Code of Regulation, Title 8 Section 5045(a) due to lack of employer knowledge.

Keywords: RIGGING, AMPUTATED, REPAIR, FINGER, WORK RULES, WELL, SLING, PUMP
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling Maintenance or repair Under $50,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300827771 Non Hospitalized injury Amputation Laborers, except construction Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing plumbing, lighting fixtures
Fatality Cause: Lifting operations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close