Accident Summary Nr: 201102993 - Employee killed when crushed between outrigger and boom

Accident Summary Nr: 201102993 -- Report ID: 0950624 -- Event Date: 10/30/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
12574975410/30/20021731238210Giacalone Electrical Services, Inc.

Abstract: On October 30, 2002, Employee #1, a backhoe operator, drove a CAT Backhoe 416C to a supply yard at a new housing development site to retrieve material. He put the backhoe in neutral, dismounted, and manually loaded several bundles of PTS pipe into the loader's bucket. Employee #1 then walked between the outrigger and the boom to place a bundle of PTS pipe on the floor between the driver's seat and the wheel well. The pipe bundle activated the left foot boom throttle; the boom crushed Employee #1 between the boom and the left outrigger, and killed him.

Keywords: OUTRIGGER, BOOM, FOOT CONTROL, CAUGHT BETWEEN, CRUSHED, PIPE, BACKHOE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Excavation, landfill New project or new addition Under $50,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 125749754 Fatality Other Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Crushed/run-over of non-operator by operating cons

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.