Accident Summary Nr: 201102662 - Employee Suffers Finger Amputation

Accident Summary Nr: 201102662 -- Report ID: 0950624 -- Event Date: 04/02/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
12584680804/11/20022448321920American Pallet

Abstract: Employee #1, a cut-off saw operator, was feeding the stock lumber under the guard. The operator operates the saw by means of a foot pedal. After the wood is positioned, the operator actuates the saw and the above-the-table guard lowers and holds the stock lumber down on the table. The saw rises from under the table to cut the wood. Employee #1 stated that he slipped and stepped on the pedal before he was ready and his hand was still holding onto the stock while under the raised guard. The guard lowered holding the operators hand between the guard and the stock, cutting off three fingers of the left hand. The above-the-table guard had not been adjusted to 0.25 in. from the stock at rest and the guard for the in-feed side had been removed allowing the operator to be exposed to the unused portion of the blade. Employee #1 was hospitalized.

Keywords: AMPUTATED, FINGER, GUARD, FOOT CONTROL, SLIP, SAW

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125846808 Hospitalized injury Amputation Sawing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close