Accident Summary Nr: 201094729 - Employee killed by fall of fork lift telescoping boom

Accident Summary Nr: 201094729 -- Report ID: 0950645 -- Event Date: 05/25/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
12613512805/25/200117990Stc Netcom

Abstract: While attempting to hook-up a cable on a tower structure, the high lift which they were using became unstable and fell to its side, causing a fatal injury to Employee #1 who was working 35-feet above on the lift. The equipment involved was a Pettibone High Lift Fork Lift with a telescoping boom. Employee #1 was employed by STC Inc. at a worksite located on top of South Mountain. Employee #1 was working on the platform 35-feet up the tower, connecting coaxial cable. Employee #1 sustain fatal multiple injuries from the fall of the high lift fork lift telescoping boom.

Keywords: PLATFORM, FRACTURE, COMMUNICATION CABLE, INDUSTRIAL TRUCK, FALL, TOWER, CONTUSION
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Tower, tank, storage elevator New project or new addition $50,000 to $250,000 3 36 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 126135128 Fatality Other Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: 35 feet
Cause: Erecting structural steel
Fatality Cause: Fall, other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.