Accident Summary Nr: 201087327 - Employee Is Killed by Electric Shock

Accident Summary Nr: 201087327 -- Report ID: 0950625 -- Event Date: 04/13/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30636148604/13/20061611237310Atlantic Concrete

Abstract: At 4:00 a.m. on April 13, 2006, Employee #1 was operating a Putzmeister Truck-Mounted Concrete Pump, Model Number 36 ES-170, using a radio signal remote control unit. Employee #1 was extending the boom up and out, and it struck an energized 12,000 volt overhead power line. Employee #1 was near the extended outrigger located by the truck driver's door when contact was made to the electrified equipment and was electrocuted. Employee #1 was killed.

Keywords: BOOM TRUCK, OVERHEAD POWER LINE, ELECTROCUTED, CONSTRUCTION, ELECTRIC SHOCK, CONCRETE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $250,000 to $500,000 2 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 306361486 Fatality Electric Shock Supervisors, material moving equipment operators Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pouring concrete floor at grade
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.