Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201085966 - Employee Amputates Fingers While Spraying Grape Vines

Accident Summary Nr: 201085966 -- Report ID: 0950625 -- Event Date: 03/21/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30635864904/01/20050172111332P & R Brar Farms

Abstract: On March 21, 2005, Employee #1, of P & R Brar Farms, was applying an herbicidal spray in the facility's vineyard. He was operating a Landini type PPHL/BA agricultural tractor, pulling the spraying machinery mounted on a trailer. The spraying mechanism is activated when one end of a rope attached to a lever on the trailer is pulled by the operator. The rope being used was sisal twine with a diameter of approximately 0.19 in. Slack in the twine between the tractor and the trailer had caused a loop to form in the line. The loop became entangled around the tractor's rear tire and suddenly pulled the twine taut, catching Employee #1's left hand between the two components and amputating three fingers. He was hospitalized.

Keywords: AMPUTATED, AGRICULTURE, FINGER, FARM MACHINERY, TRACTOR, SPRAYING RIG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 306358649 Hospitalized injury Amputation Industrial truck and tractor equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.