Accident Summary Nr: 201084274 - Employee's finger crushed by rollers

Accident Summary Nr: 201084274 -- Report ID: 0950625 -- Event Date: 07/01/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
12032122909/10/20032099311991Grimmway Farms

Abstract: On July 1, 2003, Employee #1, a welder of Grimmway Farms, was using a steel plate rolling machine. He was rolling the plate into half round saddles when his glove got caught in the rollers. Employee #1's finger tip was crushed. The machine had a constant contact operating device; however, the rollers continued to move about 1 to 1.5 revolutions more after the switch was disengaged. The employee was taken to Southern CA Orthopedic, where he was treated and released after his finger tip was surgically amputated.

Keywords: STEEL PLATE, ROTATING PARTS, AMPUTATED, STEEL, FINGER, MACHINE OPERATOR, ROLLER--MACH/PART, CAUGHT BETWEEN, CRUSHED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120321229 Non Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.