Accident Report Detail

Accident Summary Nr: 201080488 - Employee killed when caught in baler

Accident Summary Nr: 201080488 -- Report ID: 0950625 -- Event Date: 07/23/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12577493507/24/199754110Save Mart Supermarkets #51

Abstract: At approximately 10:40 p.m. on July 23, 1997, Employee #1 was working alone in the back room of a supermarket, apparently trying to remove jammed cardboard from a vertical baling machine. A coworker walked in and found Employee #1 pulled up into the baler, with his head, arm, and shoulder caught between the top of the ram and the frame. The coworker called 911. The "jaws of life" were required to extricate Employee #1, who was pronounced dead at 11:10 p.m. The baler was taken out of service until OSHA investigators arrived. A service technician operated the baler, with its gate down, and it ran until the ram hit the cardboard, whereupon it stopped. This indicated that the baler was full, and wires needed to be tied around the bale so it could be ejected. At this time, several pieces of cardboard were also found jammed against the back wall of the baler. These jammed pieces are normally removed prior to baling, sometimes with the ram in the 'down' position and sometimes in the 'up' position. Employee #1 was likely doing this at the time of the accident. The baler had an interlock, but it only prevented the baler from operating with the gate up when the START button was pushed. Once the baler was in operation, the gate could be fully opened and the ram would stop its down cycle, and cycle up. The START button could also override the interlock, if constant pressure was applied to it, allowing the gate to be open while the ram was in the up or down stroke. The employer was cited for three general and four serious violations.

Keywords: HEAD, SHOULDER, START BUTTON, WORK RULES, INTERLOCK, JAMMED, CAUGHT BETWEEN, CRUSHED, BALER, ARM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125774935 Fatality Other Stock and inventory clerks

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close