Accident Report Detail
Accident Summary Nr: 201076429 - Employee Fractures Back in Fall from Ladder
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 312686041 | 03/09/2011 | 7997 | 713910 | Steele Canyon Golf Club Corporation |
Abstract: At approximately 2:27 p.m. on February 20, 2011, Employee #1, a waiter at a golf course, was removing decorative drapes from overhead beams, while standing on a 16-ft Davidson Type III, Model Number 554-16 extension ladder. He felt the ladder jerk and then he fell from the ladder. A coworker, who was approximately 30 feet away, heard him fall, and went to his assistance. Emergency services were called, and he was taken to a nearby hospital. He fractured his back and remained hospitalized for two days. Inspection of the ladder found that the lower section had bent/buckled at a point just below the feet of the upper section. This buckling/bending of the ladder is believed to have caused the ladder to become displaced/move off the supporting beam resulting in Employee #1's fall.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 312686041 | Hospitalized injury | Fracture | Waiters'/waitresses' assistants |
Translate