Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201072196 - Employee Is Injured in Fall from Roof

Accident Summary Nr: 201072196 -- Report ID: 0950632 -- Event Date: 06/02/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
12588003906/23/20051721238320Fog Coat Corp

Abstract: At 9:24 a.m. on June 2, 2005, Employee #1, with Fog Coat Corp. (a painting and stucco repair company), was working on a roof masking a chimney. He stepped through a roof hole and fell about 17.5 feet to a concrete deck. Employee #1 was hospitalized at Scripps La Jolla Hospital for treatment of a fractured right wrist, two dislocated right fingers, and a head laceration.

Keywords: FRACTURE, HEAD, ROOF, PAINT, DISLOCATED, FALL, FALL PROTECTION, PAINTER, CHIMNEY, WRIST
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling Maintenance or repair Under $50,000 2 25

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 125880039 Hospitalized injury Fracture Painters, construction and maintenance Distance of Fall: feet
Worker Height Above Ground/Floor: 17 feet
Cause: Exterior painting
Fatality Cause: Fall from roof

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.