Accident Summary Nr: 201070976 - Employee Dies of Carbon Monoxide Poisoning

Accident Summary Nr: 201070976 -- Report ID: 0950632 -- Event Date: 02/15/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31081023902/17/20071521236115H.M. Construction Inc.

Abstract: At approximately 6:20 a.m. on February 15, 2007, an employee, a security guard for Hanna Maria Construction was found dead. The employee was transported to the San Diego Medical Examiner's office. The accident occurred inside a mobile trailer measuring about 27 feet long, 8 ft wide and 8 ft high. It was manufactured by Rosewood Enterprises (serial number R-463-828) and had two rooms. One room measured 9.98 ft by 7.25 ft, had two windows, and contained a small 2300-watt gasoline generator. (The ID sticker on electric ignition said "UST OHV 5.5 58679 123456789101112"). The generator was distributed by International Merchandising Service under the name UST, manufactured by Wennling Jennseng. The other room measured 17.03 ft by 7.25 ft and contained three windows and a blue sitting chair where the employee was found, along miscellaneous construction material and tools. The rooms were divided by a thin partition with a door. When open, the door left a space 2.67 ft wide and 6.70 ft tall. The door that separated the generator and the employee had a gap between the floor and door bottom of 1.125 in. This space was blocked with a makeshift seal, a block of wood with insulation, loosely covering the 32-in. by 1.125-in. gap. It had become a common practice to run the generator inside the trailer because the neighbors had complained of the noise. The failure to provide adequate ventilation and the placement of the generator inside the trailer were the contributing factors in this accident. Introduction of an internal combustible engine into the work area lead to an employee's overexposure of carbon monoxide.

Keywords: LUNG, ASPHYXIATED, GAS, GASOLINE, CARBON MONOXIDE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $1,000,000 to $5,000,000 2 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310810239 Fatality Asphyxia Guards and police, excluding public service Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Surveying
Fatality Cause: Asphyxiation/inhalation of toxic vapor

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.