Accident Summary Nr: 201070786 - Employee Backed over by Truck Dies from Spinal Injury

Accident Summary Nr: 201070786 -- Report ID: 0950632 -- Event Date: 03/13/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
12594515403/13/20071611237310Superior Ready Mix Concrete L.P.

Abstract: At approximately 10:30 a.m. on Tuesday, March 13, 2007, Employee #1 was working as a construction laborer for Superior Ready Mix Concrete, LP, which produces concrete, aggregate, and asphalt products and delivers and installs these products to customers throughout the San Diego, CA, area. He, a coworker, and a supervisor were at a public road asphalt repaving project in San Diego. All three were employed by Superior Ready Mix. One of Employee #1's coworkers was backing up his dump truck in the closed portion of Pomerado Road in San Diego. The firm was resurfacing the existing asphalt pavement there, by removing, grinding up, and collecting the used asphalt and then repaving the road with new asphalt. A grinding machine followed the dump truck directly, so that the waste asphalt could be collected inside the dump truck as the workers moved down the road simultaneously. Once a certain length of asphalt pavement was removed, the grinding machining and dump truck stopped. Then both the grinding machine and the dump truck, if it had not yet been filled, moved back to their beginning point to start removing another strip of asphalt parallel to the path that had been previously cut and removed. After looking in both of his rear view mirrors, the coworker driving the dump truck started to back down the road, unaware that Employee #1 was behind him, most likely in a blind spot. The coworker thought the dump truck had hit a debris pile, so he stopped the truck and got out to look. He found Employee #1 underneath the right rear wheels of the dump truck. Employee #1 had sustained fractures to the cervical portion of his spine. He was taken by ambulance to Palomar Medical Center in Escondido, where he died.

Keywords: SPINE, OBSTRUCTED REAR VIEW, DRIVER, CRUSHED, DUMP TRUCK, NECK, STRUCK BY, ASPHALT, BACKING UP, ROAD PAVING
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $50,000 to $250,000 2 24 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 125945154 Fatality Fracture Laborers, except construction Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Paving
Fatality Cause: Crushed/run-over/trapped of operator by operating

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.