Accident Summary Nr: 201067550 - Employee amputates finger in cement mixer

Accident Summary Nr: 201067550 -- Report ID: 0950632 -- Event Date: 05/22/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30702806805/28/20041742238310Quality Plastering Co

Abstract: On May 22, 2004, an employee, a foreman for a plastering crew was using battery jumper cables to start a stucco mixer. The employee placed the jumper cables through the side cover of engine guard, where a guard on the cover had been removed. When the motor on the stucco mixer started, the jumper cables were pulled into the drive belt and pulley area of the motor along with the employee's right hand, resulting in the amputation of middle finger on his right hand. His employer was a plastering contractor, working on a residential housing development. He was standing on the left side of machine when this accident occurred. The machine involved was a plaster and stucco mixer with a Company Identification Number 127. The employee was hospitalized and treated for amputation of his finger.

Keywords: AMPUTATED, CONCRETE TRUCK, FINGER, HAND
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $1,000,000 to $5,000,000 2

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 307028068 Hospitalized injury Amputation Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior masonry
Fatality Cause: Caught in stationary equipment

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.