Accident Summary Nr: 201066081 - Employee'e finger amputated by closing door

Accident Summary Nr: 201066081 -- Report ID: 0950632 -- Event Date: 11/28/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
12026948512/05/20028221611310The Scripps Research Institute

Abstract: At approximately 10:30 a.m. on November 28, 2002, Employee #1, an animal facility coordinator employed by the Scripps Research Institute, was attaching the cover to the door closer mechanism on a self-closing metal door in the laboratory. He propped the door open with a pair of forceps. He then hand tightened the two screws that hold the metal cover over the door closure device but found that the cover was still loose. The employee reached to the right to grab the forceps and the door closed, amputating the end of his middle left finger. The weight and force of the door sheared off the first knuckle of his middle finger on his left hand. The employee drove himself to the Scripps Memorial Hospital emergency room where he was treated for his injury.

Keywords: AMPUTATED, FINGER, DOOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120269485 Hospitalized injury Amputation Animal caretakers, except farm

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close