Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201065463 - Employee sustains broken leg after being struck by rebar

Accident Summary Nr: 201065463 -- Report ID: 0950632 -- Event Date: 11/08/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30079197711/14/200217910Pacific Reinforcing Steel Inc

Abstract: At approximately 8:00 a.m. on November 8, 2002, Employee #1, an iron worker, was working for Pacific Reinforcing Steel Incorporated of San Diego, California, at the San Diego Ball park construction project. Employee #1 and a coworker had rigged a bundle of 16 #8 Angle Rebar, approximately 44 ft, 10 in. long, that was located on the bed of a tractor trailer truck. They were off-loading a second bundle. They were using a Mobile Crane (Marco number 6101 Rough Terrain 65 Ton, Model Number RTC-8065, Serial Number D719- 0970) with a 20 ft Choker cable. The coworker connected his end while on the trailer and Employee #1 connected his end from the ground. The coworker signaled to Employee #1 to begin his lift and make the choker tight. Employee #1 saw that the choker was tight and turned to watch where the load was to go. However, the bundle entangled with another rebar bundle which caused four rebar in the # 7 rebar bundle to fall off the truck, hitting Employee #1 from behind. Employee #1 sustained multiple fractures to his left and right legs. He was hospitalized.

Keywords: LOADING, REBAR, IRON WORKER, MOBILE CRANE, STRUCK BY, SLING, FALLING OBJECT
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition $5,000,000 to $20,000,000 4

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300791977 Hospitalized injury Fracture Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Emplacing reinforcing steel
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.