Return to Accident Search Results
Accident Report Detail
Accident Summary Nr: 201063450 - Employee Killed in Fall From Ladder
Accident Summary Nr: 201063450 -- Report ID: 0950632 -- Event Date: 01/03/2001
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 120275540 | 01/04/2001 | 1731 | 0 | Cox Communications |
Abstract:
At approximately 10:15 a.m. on January 3, 2001, Employee #1, a cable inspector, was checking for illegal use of cable television services in a neighborhood located on a high, steep, hill. According to the employer, he placed his 28-foot extension ladder on a downward sloping ground and hooked it at the outer side of the television detection box. The weight of his body caused the top section of the ladder to slide away along the top section of the wire. The ladder was not properly placed to prevent displacement. Employee #1 fell approximately 19 feet to the asphalt road and was transported to Sharp Hospital where he was pronounced dead on arrival.
Keywords:
EXTENSION LADDER, COMMUNICATION CABLE, FALL, SLOPE
Accident Details
| End Use |
Project Type |
Project Cost |
Stories |
Non-building Height |
Fatality |
| Powerline, transmission line |
Maintenance or repair |
Under $50,000 |
|
|
X |
Employee Details
| Employee # |
Inspection Nr |
Age |
Sex |
Degree of Injury |
Nature of Injury |
Occupation |
| 1 |
120275540 |
|
|
Fatality |
Fracture |
Inspectors, testers and graders |