Accident Summary Nr: 201059177 - Employee Finger Amptated in Pallet Jack

Accident Summary Nr: 201059177 -- Report ID: 0950642 -- Event Date: 11/07/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
12607289111/15/20047363561320Alliance Workforce Solutions

Abstract: At approximately 11:10 a.m., on November 7, 2004, Employee #1 was unloading a pallet of frozen fish from the storage rack in the fresh fish cooler using a pallet jack. The pallet jack is manufactured by Crown in 2001 and the capacity is 6000 lbs, Model # PE 3540-60, Serial # 6A 190773, and weighs 3060 lbs with a 24-volt battery. The width of aisle in the fresh fish cooler is 11 ft. The bottom frame of the storage rack is 3.5 ft wide, and was located 47 inches from the floor. The standing platform was elevated 10.5 inches from the floor. The length and width of the pallet jack was 90 inches. It was found that the floor in the fresh fish cooler had 1/8 inch deep traction markings throughout the area and rock salt was sprinkled on the floor to prevent slippage. The pallet jack was not properly aligned and Employee #1 moved backward to reposition the pallet jack. As the employee pressed the handle down to move forward again, the pallet jack began to slide and continued to move backward. Employee #1 noticed that the handle of the pallet jack was getting close to the frame of the metal storage rack on the opposite side. Employee #1 jumped off the pallet jack releasing his left hand from the handle to stop the pallet jack. The pallet jack met the frame of storage rack on the opposite side and the impact of the collision broke the handle off the pallet jack. The pallet jack continued to move back crushing and amputating the employee's right middle finger. The pallet jack was inspected after the accident and it was found to be in good working condition without any deficiency. The Vernon Fire Department arrived at the site with paramedics and transported Employee #1 to the Los Angeles County USC Medical Center where he was treated and released.

Keywords: LOADING, PLATFORM, AMPUTATED, FINGER, COLLARBONE, PALLET, STORAGE RACK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 126072891 Non Hospitalized injury Amputation Industrial truck and tractor equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close