Accident Summary Nr: 201059078 - Employee is injured in violent chemical rection

Accident Summary Nr: 201059078 -- Report ID: 0950642 -- Event Date: 09/01/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30716260209/16/20042011311611Clougherty Packing Llc Dba / Farmer John

Abstract: At approximately 8:30 p.m. on September 1, 2004, Employee #1, a sanitation maintenance worker for a packing company that processes and packages pork products, was cleaning a Stephan liverwurst processing machine. The procedure for cleaning the processing machine involves a chemical named Envro T004 or trade name Boil Out. The chemical is composed of 80-sodium hydroxide and can create a violent exothermic reaction when it comes into contact with water. As a result, Employee #1 was wearing safety goggles, a safety helmet, rubber gloves, and rubber boots, but was not wearing a water repellant apron that is required by the employer for the work. Employee #1 obtained approximately 5 lbs of the total required 22 lbs of Boil Out in an open bucket to be poured into the emulsifier cooker vat of the liverwurst machine. 25 gallons of water was to be added to the chemical as well. However, the vat already contained hot water at the bottom from the previous rinsing of the machine. As Employee #1 began to pour the Boil Out into the vat, the chemical reacted violently with the water and he was sprayed with the hot water and chemical mixture. This resulted in Employee #1's hands, arms, face, chest, and abdomen to be burned. There were not witnesses to the accident. The accident investigation determined that the incident was caused by the Employee #1 not being properly shielded while mixing a chemical that reacts violently when in contact with water.

Keywords: CHEST, MAINTENANCE, ABDOMEN, GUARD, CLEANING, CHEMICAL REACTION, CHEMICAL BURN, ARM, FACE, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 307162602 Hospitalized injury Burn(Chemical) Janitors and cleaners

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close