Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201058294 - Employee is injured during crane failure

Accident Summary Nr: 201058294 -- Report ID: 0950642 -- Event Date: 12/23/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30078432901/02/20041796238290Jra Construction

Abstract: On December 23, 2003, Employee #1 was working as contracted maintenance craftsman performing a scheduled wash-up of a Tri-Nip paper press. Employee #1 secured the blind drill roll to the underside of the press roll loading arm. The roll, weighing 23,000 lbs, was suspended from a 15-ton Acco Louden bridge crane, using a 0.625-inch wire rope that was attached to a 20.50-foot spanner bar. The spanner bar weighed 2,000 lbs and supported each end of the blind drill roll. With the roll partially secured, the shank ball end of the 0.625-inch wire rope failed and the spanner bar fell forward. Employee #1 attempted to avoid the spanner bar by jumping backwards. He fell to the platform below injuring his back. Employee #1 was hospitalized at Saint Francis Hospital in Lynwood, where he was treated for a fracture to his lower vertebrae and a head laceration. He was released seven days later. A detailed investigation determined that despite the crane having been inspected by CranePro less than two months before and a new cable installed, the fractured shank ball was undersized, measuring 16 inches less in diameter than required. Additionally, the wire of the failed shank did not run all the way through the shank ball assembly. .

Keywords: FRACTURE, HEAD, INADEQUATE MAINT, LACERATION, OVERHEAD CRANE, STRUCK BY, VERTEBRA, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Manufacturing plant Maintenance or repair Under $50,000 10

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300784329 Hospitalized injury Fracture Industrial machinery repairers Distance of Fall: feet
Worker Height Above Ground/Floor: 10 feet
Cause: Installing equipment (HVAC and other)
Fatality Cause: Fall, other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close