Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201057908 - Employee injures back when ejected from power buggy

Accident Summary Nr: 201057908 -- Report ID: 0950642 -- Event Date: 09/12/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30078314909/17/20031771238110Peterson Brothers Construction

Abstract: At approximately 11:00 a.m. on September 12, 2003, Employee #1, of Peterson Brothers Construction, was using a Whiteman All-Wheel-Drive Power Buggy, model WBH-16EAWD, serial # 230235, to transport 6 in. by 12 in. by 60 mm pavers in Glendale, CA. He was going down an approximately 8.9 degree sloped ramp to an underground garage when the buggy began to pick up speed because of the steep grade. Employee #1 felt the speed was getting out of control and applied the brakes. This caused the vehicle to nose down. Employee #1 was ejected and landed on the concrete floor. He sustained back injuries and was transported by paramedics to Glendale Adventist Medical Center, where he was hospitalized for six days. Prior to the accident, the employer had removed the vehicle's original loading unit and replaced it with a platform to accommodate the pavers. The platform was not approved by the power buggy's manufacturer and it was neither designed nor installed so that the vehicle's stability while it was carrying the pavers would not be affected.

Keywords: EJECTED, IND TRK OPERATOR, WORK RULES, CONSTRUCTION, STEEP GRADE, BACK, INDUSTRIAL TRUCK, MECH MAT HANDLING, LOST CONTROL, UNSTABLE LOAD
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling New project or new addition $500,000 to $1,000,000 2 24

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300783149 Hospitalized injury Strain/Sprain Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close