Accident Report Detail
Accident Summary Nr: 201057684 - Three Employees Injured in Fall From Elevated Platform
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 300782489 | 07/25/2003 | 1541 | 236210 | Rsy Construction Inc |
Abstract: On July 25, 2003, Employees #1 through #3, of RSY Construction Incorporated, were framing the rooftop with wooden beams and joists. Employees #1 and #2 were standing on a beam that was 3.5-inches wide and 24-feet long. They were fastening joists with nail guns when Employee #3 got up to the top to collect lunch money from them. It was suspected that the beam had not yet been fastened and secured at one end. Suddenly, the beam became disengaged from the adjacent joist and fell to the concrete landing. All three employees fell approximately 20 feet to the concrete floor. Employees #2 and #3 sustained minor cuts and bruises and were transported to County USC Medical Center. Employee #1 sustained a concussion and was transported to Huntington Memorial Hospital. All three employees were hospitalized for their injuries. The investigation revealed that the accident occurred due to the lack of personal fall protection while the employees were standing on the wooden beam. The employer did not provide nor request the use of personal fall protection when the employees were required to perform work at elevated location.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Other building | New project or new addition | $500,000 to $1,000,000 | 2 | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 300782489 | Hospitalized injury | Concussion | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: 28 feet Cause: Exterior carpentry Fatality Cause: Fall from roof |
||
| 2 | 300782489 | Hospitalized injury | Bruise/Contus/Abras | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: 28 feet Cause: Exterior carpentry Fatality Cause: Fall from roof |
||
| 3 | 300782489 | Hospitalized injury | Bruise/Contus/Abras | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: 28 feet Cause: Exterior carpentry Fatality Cause: Fall from roof |