Accident Summary Nr: 201054384 - Employee's ankle fractured by rolling forklift

Accident Summary Nr: 201054384 -- Report ID: 0950642 -- Event Date: 07/04/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30077573109/06/200042250Universal Warehouses

Abstract: At approximately 12:00 midnight on July 4, 2000, Employee #1, a forklift driver at a food container warehouse, was staging materials when his Mitsubishi FGC30 forklift stalled out. He was attempting to prime the engine when the forklift jumped into reverse and started to move, catching Employee #1's ankle between the truck's body and the mast. He suffered a compound fracture of his right ankle. Since there were no coworkers present, Employee #1 rolled the forklift over to a phone and called his supervisor at home, and then summoned 911. He was transported to White Memorial Hospital, where he underwent surgery and remained for three days. Subsequent investigation determined that the accident was the result of independent employee action. The employee disregarded his training and should have reported defective equipment to maintenance and not used the forklift instead of priming the engine. In addition, the brakes had not been set on the vehicle.

Keywords: FRACTURE, IND TRK OPERATOR, VEHICLE IN GEAR, WORK RULES, CAUGHT BETWEEN, INDUSTRIAL TRUCK, MECH MAT HANDLING, UNMANNED, MECH MALFUNCTION, ANKLE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300775731 Hospitalized injury Fracture Truck drivers, light

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close